Siemens temperature measurement products that provide a 4–20 mA output signal, here are the common types used in industrial process control:
🔥 1. Temperature Transmitters (4–20 mA)These devices take a temperature sensor input (like a thermocouple or RTD) and convert it into a standard 4–20 mA output for PLC/SCADA.
Siemens Temperature Transmitter ExamplesSiemens SITRANS TF310
→ Universal temperature transmitter
→ Accepts RTD or Thermocouple input
→ Outputs 4–20 mA + HART
Siemens SITRANS TF320
→ Two‑wire transmitter for field installation
→ Output: 4–20 mA
Siemens SITRANS TF400
→ Loop powered transmitter
→ Suitable for harsh environments
👉 These transmitters mount near the sensor or in a control panel and are used when you need accurate, scalable temperature signals in a control system.
📍 2. Temperature SensorsTemperature sensors themselves (e.g., thermocouples or RTDs) do not output 4–20 mA directly — they produce a small voltage or resistance change. You must use a transmitter to convert that to a 4–20 mA industrial signal.
Examples:
PT100 RTD (platinum resistance sensor)
Thermocouple (types J, K, T, etc.)
These feed into a transmitter like the SITRANS TF series.
📊 How 4–20 mA Works for Temperature4 mA = Lowest measurement (e.g., 0°C)
20 mA = Highest measurement (e.g., 500°C)
The range can be set to match your sensor and process requirements.
The 4–20 mA signal also supplies power to the transmitter in two‑wire systems.
Two wires carry the 4–20 mA signal.
Often HART is combined with 4–20 mA for diagnostics/configuration.
Boilers
Furnaces
Heat exchangers
Chemical processes
Power plants




| Input Type | Ω, 4–20 mA, RTD |
| Output Signal | 4–20 mA |
| Head Type | Form A |
| Other Input Types | : PT-100 RTD K-TYPE |
| Sensor Input | Pt100, Pt1000 |
| Configuration | PC Configurable |
| Isolation | Isolated |
| Power Source | OUTPUT : 4 - 20 MADC --------- 2 WIRE |
| Model Name/Number | T15.H |
| Brand | WIKA |
APPLICATIONS
· PROCESS INDUSTRY
· MACHINE BUILDING AND PLANT CONSTRUCTION
SPECIAL FEATURES
· FOR THE CONNECTION OF PT100 AND PT1000 SENSORS IN A 2-, 3- OR 4-WIRE CONNECTION
· FOR THE CONNECTION OF REED CHAINS IN A POTENTIOMETER CIRCUIT
· PARAMETERISATION WITH THE WIKASOFT-TT CONFIGURATION SOFTWARE AND ELECTRICAL CONNECTION VIA QUICK CONNECTOR MAGWIK
· CONNECTION TERMINALS ALSO ACCESSIBLE FROM THE OUTSIDE
· ACCURACY < 0.2 K (< 0,36 °F) / 0.1 %
View Complete details





| Input Type | RTD + TC |
| Sensor Type | RTD |
| Output Signal | 4–20 mA HART |
| Mounting Type | Head Mount |
| Operating Range | 0-100 DEG,C |
| Sensor Input | N Type, Pt1000, K Type, Pt100, J Type, E Type, R Type, T Type |
| Measuring Range | 0–1200°C |
| Isolation | Isolated |
| Usage/Application | The SITRANS TH200 and SITRANS TH300 transmitters can be used in all industries |
| Accuracy | 0.075 |
SITRANS TH200 is designed to support all common RTDs, thermocouples, resistance and millivolt sensors. Setup is quick and easy with the transmitter modem and SIPROM T software. This configuration tool can be downloaded for free. Unique user-friendly details are implemented, one of them being the direct readout of the output current with a multimeter without having to open the 4 … 20 mA loop. A red/green LED indicates the device status at a glance.
BenefitsMeasures temperature with a linear output signal
High accuracy across entire ambient temperature range
Reduces plant noise
Alarm signal for sensor break or short-circuit according to NAMUR 43
Electro magnetic compatibility (EMC) according to DIN EN 61326 and NE21
Saves expensive compensation cables with its internal reference junction
Galvanic insulation for accuracy and safety in thermocouple applications
Single- or dual-point trim
Custom characteristic curve for application of non-standard sensors
Difference- and average- measurement
Explosion protected variants for US, Canada and Europe
Rugged design, fully potted electronics
View Complete details







| Input Type | 4–20 mA, mV, Ω, RTD, RTD + TC, Thermocouple |
| Output Signal | 4~20 mA |
| Head Type | Form A |
| Input Types | Temperature |
| Operating Range | -200 TO 600 |
| Sensor Input | B Type, T Type, K Type, Pt1000, E Type, S Type, R Type, Pt100, J Type, N Type |
| Configuration | HART Config |
| Isolation | Isolated |
| Usage/Application | RTDs, thermocouples |
| Model Name/Number | TH200 |
SITRANS TH200 is designed to support all common RTDs, thermocouples, resistance and millivolt sensors. Setup is quick and easy with the transmitter modem and SIPROM T software. This configuration tool can be downloaded for free. Unique user-friendly details are implemented, one of them being the direct readout of the output current with a multimeter without having to open the 4 … 20 mA loop. A red/green LED indicates the device status at a glance.
BenefitsMeasures temperature with a linear output signal
High accuracy across entire ambient temperature range
Reduces plant noise
Alarm signal for sensor break or short-circuit according to NAMUR 43
Electro magnetic compatibility (EMC) according to DIN EN 61326 and NE21
Saves expensive compensation cables with its internal reference junction
Galvanic insulation for accuracy and safety in thermocouple applications
Single- or dual-point trim
Custom characteristic curve for application of non-standard sensors
Difference- and average- measurement
Explosion protected variants for US, Canada and Europe
Rugged design, fully potted electronics
View Complete details







| Sensing Temperature Range | -50–150°C |
| Switch Type | SPDT |
| Contact Rating | 10 A at 250 V AC |
| Temperature Range | 10 to 300 Deg C |
| Current Rating | 15A |
| Material | Brass |
| Sensor Type | Capillary |
| Mounting Type | Bulb and Capillary |
| Enclosure Protection | IP54 |
| Cable Length | Capillary length 3 to 8 meters |
Applications
· Pump, filters
· Lubrication system, hydraulic system
· HVAC
· Circuit breakers
· Turbines
View Complete details





| Measured Parameter | Temperature |
| Output Signal | 4–20 mA HART |
| Display | LED |
| Operating Range | 0 -600 |
| Enclosure Material | Aluminium |
| Ingress Protection | IP67 |
| Hazardous Approval | Explosion Proof |
| Usage/Application | INDUSTRIAL APPLICATION |
| Model Name/Number | SITRANS TF |
| Brand | SIEMENS MAKE |
ITRANS TF
SITRANS TF is an IP67 field transmitter for heavy industrial use. It transforms resistance thermometers, thermocouples, Ohm and mV signals into a load independent DC current corresponding to sensor characteristic or a digital signal according Fieldbus standard Profibus PA or Foundation Fieldbus.
Benefits
Flexible use – Local sensing of measured values over digital display; version without transmitter
Rugged two-chamber enclosure in die-cast aluminium or stainless steel
View Complete details